Difference between revisions of "MSS60 Error: 27C6, P2096"
From Wiki-DIY
(Tag: Visual edit) |
|||
(One intermediate revision by the same user not shown) | |||
Line 2: | Line 2: | ||
− | ==== '''27C6 - P2096 ecuFault" | + | ==== '''27C6 - P2096''' ==== |
+ | {| class = "diyTable ecuFault" | ||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' | ||
Line 19: | Line 20: | ||
|Test condition: Adaptation value reaches MIN limit and hangs in this position | |Test condition: Adaptation value reaches MIN limit and hangs in this position | ||
|- | |- | ||
− | | | + | | |
|Terminal condition: Engine running | |Terminal condition: Engine running | ||
|- | |- | ||
− | | | + | | |
|Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min) | |Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min) | ||
|- | |- | ||
Line 31: | Line 32: | ||
|1. Check the fuel system and the exhaust system for leaks | |1. Check the fuel system and the exhaust system for leaks | ||
|- | |- | ||
− | | | + | | |
|2. Check pre-cat and post-cat sensors and replace as indicated | |2. Check pre-cat and post-cat sensors and replace as indicated | ||
|- | |- |
Latest revision as of 20:38, 3 February 2015
Contents
27C6 - P2096
Information saved in | DME |
Fault code | 27C6 - P2096 |
Fault text | Oxygen sensor, adaptation, trim control, bank 1 |
Fault description | Post Catalyst Fuel Trim System Too Lean (Bank 1) |
Condition for fault identification | Test condition: Adaptation value reaches MIN limit and hangs in this position |
Terminal condition: Engine running | |
Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min) | |
Condition for fault memory entry | Counter for recognition at adaptation limit >= (2x) K_LA_TRIM_DIAG_I_AD_MAX_SCHW |
Action in service | 1. Check the fuel system and the exhaust system for leaks |
2. Check pre-cat and post-cat sensors and replace as indicated | |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | none |