273F - P0050
Information saved in | DME |
Fault code | 273F - P0050 |
Fault text | Oxygen sensor final stage diagnosis heater before cat. converter, bank 2 |
Fault description | HO2S Heater Control Circuit (Bank 2 Sensor 1) |
Condition for fault identification | Test condition: Driver info includes OPENLOAD |
Terminal condition: none | |
Voltage condition: none | |
Condition for fault memory entry | 5000 ms |
Action in service | 1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B2, |
2. If OK replace oxygen sensor | |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |