Contents

2787 - P3006

Information saved in DME
Fault code 2787 - P3006
Fault text Fuel pressure, setpoint/actual-value comparison, controlled operation
Fault description Fuel Rail Pressure Pressure-Rate-Controlled, Pressure Too High
Condition for fault identification Test condition: Deviation between actual/specified pressure < -15 % (K_PKS_OBD_LL_MIN)
Terminal condition: Engine running
Voltage condition: Battery voltage > 10.9V (k_pks_obd_ub_min)
Condition for fault memory entry 10000 ms
Action in service 1. Carry out test routine
2. Check plug and wiring harness at fuel-pressure sensor, replace sensor as indicated
3. Check plug and wiring harness at the fuel pump
4. Check fuel filter and pump, replace as indicated
Fault effect and breakdown warning CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None