Difference between revisions of "MSS60 Error: 2751, P112D"
From Wiki-DIY
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |2751 - P112D |- |'''Fault text''' |Oxygen sensor fault pump current cable before catalytic converter, bank 2 |...") (Tag: Visual edit) |
|||
Line 1: | Line 1: | ||
− | {| | + | ====2751 - P112D==== |
− | + | {| class = "diyTable ecuFault" | |
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' |
Latest revision as of 20:43, 12 January 2015
2751 - P112D
Information saved in | DME |
Fault code | 2751 - P112D |
Fault text | Oxygen sensor fault pump current cable before catalytic converter, bank 2 |
Fault description | O2 Sensor Negative Current or Positive Current Control Circuit/Open (Bank 2 Sensor 1) |
Condition for fault identification | Test condition: Lambda factor lies within this range 1.001 (K_LAVK_OBD_PLAU_LAM_MIN) and 1.009 (K_LAVK_OBD_PLAU_LAM_MAX) and the post-catalyst lambda is still outside the range 88 mV (K_LAVK_OBD_PLAU_LANK_MAX) and 879 mV (K_LAVK_OBD_PLAU_LANK_MIN) OR oxygen sensor voltage |
. | Terminal condition: Engine running - Condition idle or part-load |
. | Voltage condition: none |
Condition for fault memory entry | none |
Action in service | 1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B2 (especially IP pumping current), |
. | 2. If OK, replace oxygen sensor |
Fault effect and breakdown warning | MIL lamp on after engine runs 2x /Small influence on drivability |
Driver information | Warning light: MIL |