Contents
27B8 - P0692
Information saved in | DME |
Fault code | 27B8 - P0692 |
Fault text | Electric fan, activation |
Fault description | Fan 1 Control Circuit High |
Condition for fault identification | Test condition: ATIC39 diagnosis message |
Terminal condition: TERM87 | |
Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min) | |
Condition for fault memory entry | 1000 ms |
Action in service | 1. Check plug and wire on ELUE |
2. Check signal wire in wiring harness on DME | |
3. Replace ELUE | |
Fault effect and breakdown warning | Fan has failed |
Constant rise in engine temperature leading to CC message | |
Driver information | Warning light: none |
Service instruction | none |