Difference between revisions of "MSS60 Error: 27E4, P1209"

From Wiki-DIY
Jump to: navigation, search
 
Line 20: Line 20:
 
|Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation
 
|Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation
 
|-
 
|-
|'''.'''
+
|
 
|Terminal condition: TERM87
 
|Terminal condition: TERM87
 
|-
 
|-
|'''.'''
+
|
 
|Voltage condition: none
 
|Voltage condition: none
 
|-
 
|-
Line 32: Line 32:
 
|1. Check ELUP fuse,
 
|1. Check ELUP fuse,
 
|-
 
|-
|'''.'''
+
|
 
|2. Check wires,
 
|2. Check wires,
 
|-
 
|-
|'''.'''
+
|
 
|3. Replace ELUP
 
|3. Replace ELUP
 
|-
 
|-
Line 41: Line 41:
 
|CC message
 
|CC message
 
|-
 
|-
|'''.'''
+
|
 
|Engine speed limited
 
|Engine speed limited
 
|-
 
|-
|'''.'''
+
|
 
|Reduced power
 
|Reduced power
 
|-
 
|-
|'''.'''
+
|
 
|MIL after engine runs 2x
 
|MIL after engine runs 2x
 
|-
 
|-

Latest revision as of 20:40, 3 February 2015


Contents

27E4 - P1209

Information saved in DME
Fault code 27E4 - P1209
Fault text Vacuum sensor, brake booster, plausibility
Fault description Brake Booster Pump Shutoff Valve Plausibility
Condition for fault identification Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation
Terminal condition: TERM87
Voltage condition: none
Condition for fault memory entry 5000 ms
Action in service 1. Check ELUP fuse,
2. Check wires,
3. Replace ELUP
Fault effect and breakdown warning CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None