Difference between revisions of "MSS60 Error: 271B, P0015"

From Wiki-DIY
Jump to: navigation, search
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |271B - P0015 |- |'''Fault text''' |VANOS control, exhaust bank 1 |- |'''Fault description''' |'B' Camshaft Pos...")
(No difference)

Revision as of 07:25, 11 January 2015

Information saved in DME
Fault code 271B - P0015
Fault text VANOS control, exhaust bank 1
Fault description 'B' Camshaft Position - Timing Over-Retarded (Bank 1)
Condition for fault identification Test condition: Filtered control deviation > 8.0°Crankshaft (K_VAN_XD_FILT_ED)
Terminal condition: Terminal 15
Voltage condition: Battery voltage > 9V (k_ed_ubmin)
Condition for fault memory entry 1
Action in service 1. Clear fault memory, VANOS system test
2. Check valves, check adjuster
Fault effect and breakdown warning Error display in instrument / power reduction / engine speed governed to 7000 rpm / MIL on after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None