Difference between revisions of "MSS60 Error: 2724, P0132"
From Wiki-DIY
(Created page with "{| |'''Information saved in''' |DME |- |'''Fault code''' |2724 - P0132 |- |'''Fault text''' |Oxygen sensor, signal before cat., bank 1 |- |'''Fault description''' |O2 Sensor C...") (Tag: Visual edit) |
|||
Line 1: | Line 1: | ||
− | {| | + | ====2724 - P0132==== |
+ | |||
+ | {| class = "diyTable ecuFault" | ||
|'''Information saved in''' | |'''Information saved in''' | ||
|DME | |DME |
Latest revision as of 03:17, 12 January 2015
2724 - P0132
Information saved in | DME |
Fault code | 2724 - P0132 |
Fault text | Oxygen sensor, signal before cat., bank 1 |
Fault description | O2 Sensor Circuit High Voltage (Bank 1 Sensor 1) |
Condition for fault identification | Test condition: lavk_atic42_pin_diag_b1 BIT1 or BIT3 or BIT5 or BIT7 set |
Terminal condition: none | |
Voltage condition: none | |
Condition for fault memory entry | 3000 ms |
Action in service | 1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B1, |
2. If OK replace oxygen sensor | |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | None |