Difference between revisions of "MSS60 Error: 2743, P0155"
From Wiki-DIY
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |2743 - P0155 |- |'''Fault text''' |Oxygen sensor heater resistance diagnosis before cat. converter, bank 2 |-...") (Tag: Visual edit) |
|||
Line 1: | Line 1: | ||
− | {| | + | ====2743 - P0155==== |
− | + | {| class = "diyTable ecuFault" | |
− | |||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' |
Latest revision as of 20:40, 12 January 2015
2743 - P0155
Information saved in | DME |
Fault code | 2743 - P0155 |
Fault text | Oxygen sensor heater resistance diagnosis before cat. converter, bank 2 |
Fault description | O2 Sensor Heater Circuit (Bank 2 Sensor 1) |
Condition for fault identification | Test condition: The upper or lower threshold of the resistance values has been violated, above/below 6.0 ohms (K_LSHVK_DIAG_RU) 14.5 ohms (K_LSHVK_DIAG_RO) |
Terminal condition: Engine running | |
Voltage condition: Battery voltage > 9V (k_ed_ubmin) | |
Condition for fault memory entry | min. K_LSHVK_DIAG_ANZ_MESS (100) valid calculations of heater resistance - roughly.1.5 sec. |
Action in service | 1. DME software release must be more recent than 07-06-510, fix incorporated since 07-09-521 |
2. Check plug, wiring harness on pre-cat oxygen sensor LSVK B2, | |
3. If OK, replace oxygen sensor | |
Fault effect and breakdown warning | MIL lamp on after engine runs 2x /Small influence on drivability |
Driver information | Warning light: MIL |
Service instruction | None |