Difference between revisions of "MSS60 Error: 278A, P0430"

From Wiki-DIY
Jump to: navigation, search
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |278A - P0430 |- |'''Fault text''' |Catalytic-converter conversion, bank 2 |- |'''Fault description''' |Catalys...")
 
 
Line 1: Line 1:
{|
+
====278A - P0430====
|
+
{| class = "diyTable ecuFault"
|
 
 
|-
 
|-
 
|'''Information saved in'''
 
|'''Information saved in'''

Latest revision as of 20:51, 12 January 2015

278A - P0430

Information saved in DME
Fault code 278A - P0430
Fault text Catalytic-converter conversion, bank 2
Fault description Catalyst System Efficiency Below Threshold (Bank 2)
Condition for fault identification Test condition: Diagnosis value above threshold K_KAT_OBD_WERT_MAX
Terminal condition: Engine running - Condition idle or part-load
Voltage condition: none
Condition for fault memory entry none
Action in service 1. Check exhaust system for leaks
2. No faults related to oxygen sensor or fuel system or VANOS should be present
3. Conduct oxygen sensor test routines, even if no oxygen sensor fault is present.
4. Replace catalytic conveter near engine
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL
Service instruction None