Information saved in DME
Fault code 27B8 - P0692
Fault text Electric fan, activation
Fault description Fan 1 Control Circuit High
Condition for fault identification Test condition: ATIC39 diagnosis message
. Terminal condition: TERM87
. Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min)
Condition for fault memory entry 1000 ms
Action in service 1. Check plug and wire on ELUE
. 2. Check signal wire in wiring harness on DME
. 3. Replace ELUE
Fault effect and breakdown warning Fan has failed
. Constant rise in engine temperature leading to CC message
Driver information Warning light: none
Service instruction none