Difference between revisions of "MSS60 Error: 27B8, P0692"

From Wiki-DIY
Jump to: navigation, search
 
Line 20: Line 20:
 
|Test condition: ATIC39 diagnosis message
 
|Test condition: ATIC39 diagnosis message
 
|-
 
|-
|'''.'''
+
|
 
|Terminal condition: TERM87
 
|Terminal condition: TERM87
 
|-
 
|-
|'''.'''
+
|
 
|Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min)
 
|Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min)
 
|-
 
|-
Line 32: Line 32:
 
|1. Check plug and wire on ELUE
 
|1. Check plug and wire on ELUE
 
|-
 
|-
|'''.'''
+
|
 
|2. Check signal wire in wiring harness on DME
 
|2. Check signal wire in wiring harness on DME
 
|-
 
|-
|'''.'''
+
|
 
|3. Replace ELUE
 
|3. Replace ELUE
 
|-
 
|-
Line 41: Line 41:
 
|Fan has failed
 
|Fan has failed
 
|-
 
|-
|'''.'''
+
|
 
|Constant rise in engine temperature leading to CC message
 
|Constant rise in engine temperature leading to CC message
 
|-
 
|-

Latest revision as of 20:28, 3 February 2015


Contents

27B8 - P0692

Information saved in DME
Fault code 27B8 - P0692
Fault text Electric fan, activation
Fault description Fan 1 Control Circuit High
Condition for fault identification Test condition: ATIC39 diagnosis message
Terminal condition: TERM87
Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min)
Condition for fault memory entry 1000 ms
Action in service 1. Check plug and wire on ELUE
2. Check signal wire in wiring harness on DME
3. Replace ELUE
Fault effect and breakdown warning Fan has failed
Constant rise in engine temperature leading to CC message
Driver information Warning light: none
Service instruction none