Difference between revisions of "MSS60 Error: 27C6, P2096"
From Wiki-DIY
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27C6 - P2096 |- |'''Fault text''' |Oxygen sensor, adaptation, trim control, bank 1 |- |'''Fault description'''...") (Tag: Visual edit) |
(No difference)
|
Revision as of 20:37, 3 February 2015
Information saved in | DME |
Fault code | 27C6 - P2096 |
Fault text | Oxygen sensor, adaptation, trim control, bank 1 |
Fault description | Post Catalyst Fuel Trim System Too Lean (Bank 1) |
Condition for fault identification | Test condition: Adaptation value reaches MIN limit and hangs in this position |
. | Terminal condition: Engine running |
. | Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min) |
Condition for fault memory entry | Counter for recognition at adaptation limit >= (2x) K_LA_TRIM_DIAG_I_AD_MAX_SCHW |
Action in service | 1. Check the fuel system and the exhaust system for leaks |
. | 2. Check pre-cat and post-cat sensors and replace as indicated |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | none |