Difference between revisions of "MSS60 Error: 27C6, P2096"
From Wiki-DIY
Line 2: | Line 2: | ||
− | ==== '''27C6 - P2096 ecuFault" | + | ==== '''27C6 - P2096''' ==== |
+ | {| class = "diyTable ecuFault" | ||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' |
Revision as of 20:38, 3 February 2015
Contents
27C6 - P2096
Information saved in | DME |
Fault code | 27C6 - P2096 |
Fault text | Oxygen sensor, adaptation, trim control, bank 1 |
Fault description | Post Catalyst Fuel Trim System Too Lean (Bank 1) |
Condition for fault identification | Test condition: Adaptation value reaches MIN limit and hangs in this position |
. | Terminal condition: Engine running |
. | Voltage condition: Battery voltage > 9.8V (k_diag_tr_ub_min) |
Condition for fault memory entry | Counter for recognition at adaptation limit >= (2x) K_LA_TRIM_DIAG_I_AD_MAX_SCHW |
Action in service | 1. Check the fuel system and the exhaust system for leaks |
. | 2. Check pre-cat and post-cat sensors and replace as indicated |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |