Difference between revisions of "MSS60 Error: 27E4, P1209"

From Wiki-DIY
Jump to: navigation, search
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27E4 - P1209 |- |'''Fault text''' |Vacuum sensor, brake booster, plausibility |- |'''Fault description''' |Bra...")
(No difference)

Revision as of 20:40, 3 February 2015

Information saved in DME
Fault code 27E4 - P1209
Fault text Vacuum sensor, brake booster, plausibility
Fault description Brake Booster Pump Shutoff Valve Plausibility
Condition for fault identification Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation
. Terminal condition: TERM87
. Voltage condition: none
Condition for fault memory entry 5000 ms
Action in service 1. Check ELUP fuse,
. 2. Check wires,
. 3. Replace ELUP
Fault effect and breakdown warning CC message
. Engine speed limited
. Reduced power
. MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None