Difference between revisions of "MSS60 Error: 27E4, P1209"
From Wiki-DIY
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27E4 - P1209 |- |'''Fault text''' |Vacuum sensor, brake booster, plausibility |- |'''Fault description''' |Bra...") (Tag: Visual edit) |
|||
Line 1: | Line 1: | ||
− | + | __FORCETOC__ | |
− | + | ||
− | | | + | |
+ | ==== '''27E4 - P1209''' ==== | ||
+ | {| class = "diyTable ecuFault" | ||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' |
Revision as of 20:40, 3 February 2015
Contents
27E4 - P1209
Information saved in | DME |
Fault code | 27E4 - P1209 |
Fault text | Vacuum sensor, brake booster, plausibility |
Fault description | Brake Booster Pump Shutoff Valve Plausibility |
Condition for fault identification | Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation |
. | Terminal condition: TERM87 |
. | Voltage condition: none |
Condition for fault memory entry | 5000 ms |
Action in service | 1. Check ELUP fuse, |
. | 2. Check wires, |
. | 3. Replace ELUP |
Fault effect and breakdown warning | CC message |
. | Engine speed limited |
. | Reduced power |
. | MIL after engine runs 2x |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |