Difference between revisions of "MSS60 Error: 2B21, P1628"

From Wiki-DIY
Jump to: navigation, search
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |2B21 - P1628 |- |'''Fault text''' |Throttle-valve actuator pre-drive check, bank 1 |- |'''Fault description'''...")
(No difference)

Revision as of 21:09, 3 February 2015

Information saved in DME
Fault code 2B21 - P1628
Fault text Throttle-valve actuator pre-drive check, bank 1
Fault description Throttle Valve Actuator Spring Test Malfunction during Opening (Bank 1)
Condition for fault identification Test condition: Wire permanently disabled
Terminal condition: TERM87
Voltage condition: none
Condition for fault memory entry 300 ms
Action in service 1. Check enable wire B1
2. Clear fault memory, perform EDR electronic throttle valve control system test
3. Replace EDR1
Fault effect and breakdown warning CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None