Difference between revisions of "MSS60 Error: 2722, P0092"
From Wiki-DIY
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |2722 - P0092 |- |'''Fault text''' |Fuel-pressure sensor, signal |- |'''Fault description''' |Fuel Pressure Reg...") (Tag: Visual edit) |
(No difference)
|
Revision as of 01:32, 8 February 2015
Information saved in | DME |
Fault code | 2722 - P0092 |
Fault text | Fuel-pressure sensor, signal |
Fault description | Fuel Pressure Regulator 1 Control Circuit High |
Condition for fault identification | Test condition: Sensor value > 9.5 bar (K_PKS_DIAG_MAX) |
Terminal condition: TERM87 | |
Voltage condition: None | |
Condition for fault memory entry | 5 ms |
Action in service | 1. Clear fault memory, PKS system test |
2. Check plug and wiring harness to PKS | |
3. If OK, replace sensor | |
Fault effect and breakdown warning | MIL lamp comes on after engine runs 2x |
CC message / display for governed rpm / reduced power | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |