MSS60 Error: 273E, P0030

From Wiki-DIY
Revision as of 05:20, 12 January 2015 by Rcollins (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

273E - P0030

Information saved in DME
Fault code 273E - P0030
Fault text Oxygen sensor final stage diagnosis heater before cat. converter, bank 1
Fault description HO2S Heater Control Circuit (Bank 1 Sensor 1)
Condition for fault identification Test condition: Driver info includes OPENLOAD
Terminal condition: none
Voltage condition: none
Condition for fault memory entry 5000 ms
Action in service 1. Check plug and wiring harness on pre-cat oxygen sensor LSVK B1,
2. If OK replace oxygen sensor
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL
Service instruction None