MSS60 Error: 27B2, P1412

From Wiki-DIY
Revision as of 20:27, 3 February 2015 by Rcollins (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search


Contents

27B2 - P1412

Information saved in DME
Fault code 27B2 - P1412
Fault text Secondary air system flow rate, main branch
Fault description Secondary Air Pump/Secondary Air Valve Large Leak
Condition for fault identification Test condition: sls_obdh_mdf_max_intg_norm (after roughly 30s) < K_SLS_OBDH_MDF_MIN_DEF and
sls_obdh_lam_asv_intg_norm < k_SLS_OBDH_MDF_1_MAG and > k_SLS_OBDH_MDF_2_MAG or
Terminal condition: Engine running
Voltage condition: Battery voltage > 10.8 V (k_sls_obd_ub_min)
Condition for fault memory entry 30000 ms
Action in service 1. Check main harness for leaks and replace secondary air line as indicated
Fault effect and breakdown warning MIL is on after 2x engine cold start
Driver information Warning light: MIL
Service instruction None