MSS60 Error: 27E4, P1209
From Wiki-DIY
Contents
27E4 - P1209
Information saved in | DME |
Fault code | 27E4 - P1209 |
Fault text | Vacuum sensor, brake booster, plausibility |
Fault description | Brake Booster Pump Shutoff Valve Plausibility |
Condition for fault identification | Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation |
Terminal condition: TERM87 | |
Voltage condition: none | |
Condition for fault memory entry | 5000 ms |
Action in service | 1. Check ELUP fuse, |
2. Check wires, | |
3. Replace ELUP | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |