2B20 - P0222

Information saved in DME
Fault code 2B20 - P0222
Fault text Throttle-valve sensor, bank 2
Fault description Throttle/Pedal Position Sensor/Switch 'B' Circuit Low
Condition for fault identification Test condition: Measured value <= 0.2V (K_EGAS_WDK_MIN)
Terminal condition: TERM87
Voltage condition: None
Condition for fault memory entry 100 ms
Action in service 1. Check plug and wiring harness,
2. Check installation of throttle valve sensor DKG2,
3. Replace DKG2
Fault effect and breakdown warning CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None


2B20 - P0223

Information saved in DME
Fault code 2B20 - P0223
Fault text Throttle-valve sensor, bank 2
Fault description Throttle/Pedal Position Sensor/Switch 'B' Circuit High
Condition for fault identification Test condition: Measured value >= 4.8V (K_EGAS_WDK_MAX)
Terminal condition: TERM87
Voltage condition: None
Condition for fault memory entry 100 ms
Action in service 1. Check plug and wiring harness,
2. Check installation of throttle valve sensor DKG2,
3. Replace DKG2
Fault effect and breakdown warning CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information Warning light: MIL, EML, CC message, backup program
Service instruction None