MSS60 Error: 271B, P0015
From Wiki-DIY
Information saved in | DME |
Fault code | 271B - P0015 |
Fault text | VANOS control, exhaust bank 1 |
Fault description | 'B' Camshaft Position - Timing Over-Retarded (Bank 1) |
Condition for fault identification | Test condition: Filtered control deviation > 8.0°Crankshaft (K_VAN_XD_FILT_ED) |
Terminal condition: Terminal 15 | |
Voltage condition: Battery voltage > 9V (k_ed_ubmin) | |
Condition for fault memory entry | 1 |
Action in service | 1. Clear fault memory, VANOS system test |
2. Check valves, check adjuster | |
Fault effect and breakdown warning | Error display in instrument / power reduction / engine speed governed to 7000 rpm / MIL on after engine runs 2x |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |