MSS60 Error: 278A, P0430
From Wiki-DIY
Information saved in | DME |
Fault code | 278A - P0430 |
Fault text | Catalytic-converter conversion, bank 2 |
Fault description | Catalyst System Efficiency Below Threshold (Bank 2) |
Condition for fault identification | Test condition: Diagnosis value above threshold K_KAT_OBD_WERT_MAX |
Terminal condition: Engine running - Condition idle or part-load | |
Voltage condition: none | |
Condition for fault memory entry | none |
Action in service | 1. Check exhaust system for leaks |
2. No faults related to oxygen sensor or fuel system or VANOS should be present | |
3. Conduct oxygen sensor test routines, even if no oxygen sensor fault is present. | |
4. Replace catalytic conveter near engine | |
Fault effect and breakdown warning | MIL on after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | None |