MSS60 Error: 27E4, P1209
From Wiki-DIY
Contents
27E4 - P1209
Information saved in | DME |
Fault code | 27E4 - P1209 |
Fault text | Vacuum sensor, brake booster, plausibility |
Fault description | Brake Booster Pump Shutoff Valve Plausibility |
Condition for fault identification | Test condition: Constant violations of activation threshold or vacuum gradient is too low during activation |
. | Terminal condition: TERM87 |
. | Voltage condition: none |
Condition for fault memory entry | 5000 ms |
Action in service | 1. Check ELUP fuse, |
. | 2. Check wires, |
. | 3. Replace ELUP |
Fault effect and breakdown warning | CC message |
. | Engine speed limited |
. | Reduced power |
. | MIL after engine runs 2x |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |