MSS60 Error: 2729, P2298

From Wiki-DIY
Revision as of 03:35, 12 January 2015 by Rcollins (talk | contribs) (Created page with "{| |'''Information saved in''' |DME |- |'''Fault code''' |2729 - P2298 |- |'''Fault text''' |Oxygen sensor, coast-mode diagnosis before cat., bank 2 |- |'''Fault description''...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search
Information saved in DME
Fault code 2729 - P2298
Fault text Oxygen sensor, coast-mode diagnosis before cat., bank 2
Fault description O2 Sensor Out of Range During Deceleration (Bank 2 Sensor 1)
Condition for fault identification Test condition: Oxygen sensor is available (via sensor temperature, no error code entries, etc.) but the AD value is less than 3398mV (K_LAVK_OBD_SA_SCHW) for a number of 2 (K_LAVK_OBD_SA_CNT) measurements
. Terminal condition: Engine running - overrun condition
. Voltage condition: none
Condition for fault memory entry none
Action in service 1. Check plug and wiring harness to pre-cat oxygen sensor LSVK B2 (focus on opens in wires for virtual ground and pumping current)
. 2. Replace oxygen sensor
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL
Service instruction none