MSS60 Error: 27AB, P0068, P0106, P2193

From Wiki-DIY
Revision as of 20:20, 3 February 2015 by Rcollins (talk | contribs) (Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |27AB - P0106 |- |'''Fault text''' |Charge plausibility, diagnosis hot - bank 2 |- |'''Fault description''' |Ma...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search
Information saved in DME
Fault code 27AB - P0106
Fault text Charge plausibility, diagnosis hot - bank 2
Fault description Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Range/Performance
Condition for fault identification Test condition: Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to rpm/load factor) KF_FPLAU_OBD_PSAU_DELTA_ML_MAX * expansion factors (K_FPLAU_OBD_TE_F, KL_FPLAU_PSAU_PUMG_F)
Terminal condition: Engine running
Voltage condition: none
Condition for fault memory entry 10000 ms
Action in service 1. Check induction system B1 for leaks
2. Replace intake manifold pressure sensor
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL
Service instruction None



Information saved in DME
Fault code 27AB - P0068
Fault text Charge plausibility, diagnosis hot - bank 2
Fault description MAP/MAF - Throttle Position Correlation
Condition for fault identification Test condition: Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to rpm/load factor) KF_FPLAU_OBD_AQ_DELTA_ML_MAX * expansion factor (K_FPLAU_OBD_TE_F)
Terminal condition: Engine running
Voltage condition: none
Condition for fault memory entry 10000 ms
Action in service 1. Check induction system B1 for leaks
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL
Service instruction None



Information saved in DME
Fault code 27AB - P2193
Fault text Charge plausibility, diagnosis hot - bank 2
Fault description System Too Lean at Higher Load (Bank 2)
Condition for fault identification Test condition: Deviation from mean value (depending on psau, lam, aq) in percent is determined and compared with the max. deviation (in relation to rpm/load factor) KF_FPLAU_OBD_AQ_DELTA_ML_MAX * expansion factor (K_FPLAU_OBD_TE_F)
Terminal condition: Engine running
Voltage condition: none
Condition for fault memory entry 10000 ms
Action in service 1. Check induction system B1 for leaks
Fault effect and breakdown warning MIL on after engine runs 2x
Driver information Warning light: MIL
Service instruction None