MSS60 Error: 2742, P0135
From Wiki-DIY
Contents
2742 - P0135
Information saved in | DME |
Fault code | 2742 - P0135 |
Fault text | Oxygen sensor heater resistance diagnosis before cat. converter, bank 1 |
Fault description | O2 Sensor Heater Circuit (Bank 1 Sensor 1) |
Condition for fault identification | Test condition: The upper or lower threshold of the resistance values has been violated, above/below 6.0 ohms (K_LSHVK_DIAG_RU) 14.5 ohms (K_LSHVK_DIAG_RO) |
Terminal condition: Engine running | |
Voltage condition: Battery voltage > 9V (k_ed_ubmin) | |
Condition for fault memory entry | min. K_LSHVK_DIAG_ANZ_MESS (100) valid calculations of heater resistance - roughly.1.5 sec. |
Action in service | 1. DME software release must be more recent than 07-06-510, fix incorporated since 07-09-521 |
2. Check plug, wiring harness on pre-cat oxygen sensor LSVK B1, | |
3. If OK, replace oxygen sensor | |
Fault effect and breakdown warning | MIL lamp on after engine runs 2x /Small influence on drivability |
Driver information | Warning light: MIL |
Service instruction | None |
MIL after engine runs 2x |