MSS60 Error: 2771, P0133
From Wiki-DIY
Information saved in | DME |
Fault code | 2771 - P0133 |
Fault text | Oxygen sensor dynamic diagnosis before catalytic converter, bank 1 |
Fault description | O2 Sensor Circuit Slow Response (Bank 1 Sensor 1) |
Condition for fault identification | Test condition: Amplitude of oxygen sensor less than diag. value 0.35 (K_LAVK_OBD_DYN_WERT_MAX) |
Terminal condition: Engine running - Condition idle or part-load | |
Voltage condition: None | |
Condition for fault memory entry | None |
Action in service | 1. Clear fault memory, oxygen sensor system test |
2. Check exhaust system for leaks | |
3. Replace pre-cat oxygen sensor LSVK B1 | |
Fault effect and breakdown warning | MIL on after engine runs 2x / possible mild effect on drivability...surge during steady-state operation |
Driver information | Warning light: MIL |
Service instruction | None |