MSS60 Error: 275E, P0175
From Wiki-DIY
275E - P0175
Information saved in | DME |
Fault code | 275E - P0175 |
Fault text | Oxygen sensor limit position fault bank 2 |
Fault description | System Too Rich (Bank 2) |
Condition for fault identification | Test condition: Controller pegged at MAX threshold 1.25 (K_LAM_REG_F_MAX) for time of at least 30 sec. (K_LAM_DIAG_REG_T) |
. | Terminal condition: Engine running |
. | Voltage condition: none |
Condition for fault memory entry | Controller limit for K_LAM_DIAG_REG_T (60s) |
Action in service | 1. Check fuel system for leaks, initiate test routine as indicated |
. | 2. Check exhaust system for leaks |
. | 3. Check HFM for leaks and correct operation |
. | 4. Read out oxygen sensor diagnostic data, perform both oxygen sensor test routines as indicated |
Fault effect and breakdown warning | Engine runs erratically / Potential collateral error: Miss errors and lamda error MIL after engine runs 2x |
Driver information | Warning light: MIL |
Service instruction | none |