MSS60 Error: 2B0D, P152C, P152D, P152E, P152F
From Wiki-DIY
2B0D - P152C
Information saved in | DME |
Fault code | 2B0D - P152C |
Fault text | Idle actuator monitoring, bank 1 |
Fault description | Idle-Speed Control Valve Monitoring Dissimilar Desired Values (Bank 1) |
Condition for fault identification | Test condition: Difference too large |
Terminal condition: TERM87 | |
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min) | |
Condition for fault memory entry | 300 ms |
Action in service | 1. Clear fault memory, LLS idle actuator system test |
2. Check LLS1 voltage supply | |
3. Replace LLS1 | |
Fault effect and breakdown warning | DSC lamp / CC message / engine speed limited to 5000 rpm / reduced power / engine start may be possible only with use of accelerator pedal |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B0D - P152D
Information saved in | DME |
Fault code | 2B0D - P152D |
Fault text | Idle actuator monitoring, bank 1 |
Fault description | Idle-Speed Control Valve Monitoring Incorrect Actual Value (Bank 1) |
Condition for fault identification | Test condition: Error detection received via CAN |
Terminal condition: TERM87 | |
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min) | |
Condition for fault memory entry | 100 ms |
Action in service | 1. Clear fault memory, LLS idle actuator system test |
2. Check LLS1 voltage supply | |
3. Replace LLS1 | |
Fault effect and breakdown warning | DSC lamp / CC message / engine speed limited to 5000 rpm / reduced power / engine start may be possible only with use of accelerator pedal |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B0D - P152E
Information saved in | DME |
Fault code | 2B0D - P152E |
Fault text | Idle actuator monitoring, bank 1 |
Fault description | Idle-Speed Control Valve Monitoring Actual Value / Desired Value Correlation (Bank 1) |
Condition for fault identification | Test condition: Difference too large |
Terminal condition: TERM87 | |
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min) | |
Condition for fault memory entry | 350 ms |
Action in service | 1. Clear fault memory, LLS idle actuator system test |
2. Check LLS1 voltage supply | |
3. Replace LLS1 | |
Fault effect and breakdown warning | DSC lamp / CC message / engine speed limited to 5000 rpm / reduced power / engine start may be possible only with use of accelerator pedal |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B0D - P152F
Information saved in | DME |
Fault code | 2B0D - P152F |
Fault text | Idle actuator monitoring, bank 1 |
Fault description | Idle-Speed Control Valve Monitoring Reset Error (Bank 1) |
Condition for fault identification | Test condition: Not identical for too long |
Terminal condition: TERM87 | |
Voltage condition: Battery voltage > 6.8V (k_egas_can_ed_ub_min) | |
Condition for fault memory entry | 250 ms |
Action in service | 1. Clear fault memory, LLS idle actuator system test |
2. Check LLS1 voltage supply | |
3. Replace LLS1 | |
Fault effect and breakdown warning | DSC lamp / CC message / engine speed limited to 5000 rpm / reduced power / engine start may be possible only with use of accelerator pedal |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |