MSS60 Error: 2B15, P0638, P1636, P2100
From Wiki-DIY
2B15 - P1636
Information saved in | DME |
Fault code | 2B15 - P1636 |
Fault text | Throttle-valve actuator, governor monitoring, bank 1 |
Fault description | Throttle Valve Circuit (Bank 1) |
Condition for fault identification | Test condition: Actuator shifts to Failsafe mode |
Terminal condition: TERM87 | |
Voltage condition: None | |
Condition for fault memory entry | 10 ms |
Action in service | 1. Clear fault memory, conduct EDR electronic throttle valve control system test, |
2. Check plug and wiring harness at throttle valve sensor DKG1 and electronic throttle valve control EDR1, | |
3. Replace DKG1 or EDR for Bank 1 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B15 - P2100
Information saved in | DME |
Fault code | 2B15 - P2100 |
Fault text | Throttle-valve actuator, governor monitoring, bank 1 |
Fault description | Throttle Actuator 'A' Control Motor Circuit/Open |
Condition for fault identification | Test condition: Actuator shifts to Failsafe mode |
Terminal condition: TERM87 | |
Voltage condition: None | |
Condition for fault memory entry | 10 ms |
Action in service | 1. Clear fault memory, conduct EDR electronic throttle valve control system test, |
2. Check plug and wiring harness at throttle valve sensor DKG1 and electronic throttle valve control EDR1, | |
3. Replace DKG1 or EDR for Bank 1 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B15 - P0638
Information saved in | DME |
Fault code | 2B15 - P0638 |
Fault text | Throttle-valve actuator, governor monitoring, bank 1 |
Fault description | Throttle Actuator Control Range/Performance (Bank 1) |
Condition for fault identification | Test condition: Actuator reports system error |
Terminal condition: TERM87 | |
Voltage condition: None | |
Condition for fault memory entry | 10 ms |
Action in service | 1. Clear fault memory, conduct EDR electronic throttle valve control system test, |
2. Check plug and wiring harness at throttle valve sensor DKG1 and electronic throttle valve control EDR1, | |
3. Replace DKG1 or EDR for Bank 1 | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |
2B15 - P0638
Information saved in | DME |
Fault code | 2B15 - P0638 |
Fault text | Throttle-valve actuator, governor monitoring, bank 1 |
Fault description | Throttle Actuator Control Range/Performance (Bank 1) |
Condition for fault identification | Test condition: Actuator reports regulator error |
Terminal condition: TERM87 | |
Voltage condition: None | |
Condition for fault memory entry | 10 ms |
Action in service | 1. Clear fault memory, carry out EDR electronic throttle valve control system test, |
2. Check plug and wiring harness to throttle valve sensor DKG1 and EDR1, | |
3. Replace DKG1 or EDR Bank 1, | |
4. With UMWB engine protection check throttle valve assembly for stiction | |
Fault effect and breakdown warning | CC message |
Engine speed limited | |
Reduced power | |
MIL after engine runs 2x | |
Driver information | Warning light: MIL, EML, CC message, backup program |
Service instruction | None |