MSS60 Error: CDB6, UNK01

From Wiki-DIY
Jump to: navigation, search


Contents

CDB6 - UNK01

Information saved in DME
Fault code CDB6
Fault text Diagnosis monitors the required torque.
Fault description Malfunction monitoring conditions The fault is detected if the torque is higher than the required torque.
Condition for fault identification Test condition:
Temperature condition - None
Time condition - None
Other preconditions - None
Terminal status - Terminal 15
Voltage precondition: Vehicle voltage between 9V and 16V
Condition for fault memory entry The fault is entered immediately.
Action in service Carry out bus system analysis
Fault effect and breakdown warning None
Driver information None
Service instruction None