Difference between revisions of "MSS60 Error: CDB6, UNK01"
From Wiki-DIY
(Created page with "{| | | |- |'''Information saved in''' |DME |- |'''Fault code''' |CDB6 |- |'''Fault text''' |Diagnosis monitors the required torque. |- |'''Fault description''' |Malfunction mo...") (Tag: Visual edit) |
|||
Line 1: | Line 1: | ||
− | + | __FORCETOC__ | |
− | + | ||
− | | | + | |
+ | ==== '''CDB6 - UNK01''' ==== | ||
+ | {| class = "diyTable ecuFault" | ||
|- | |- | ||
|'''Information saved in''' | |'''Information saved in''' |
Latest revision as of 21:25, 3 February 2015
Contents
CDB6 - UNK01
Information saved in | DME |
Fault code | CDB6 |
Fault text | Diagnosis monitors the required torque. |
Fault description | Malfunction monitoring conditions The fault is detected if the torque is higher than the required torque. |
Condition for fault identification | Test condition: |
Temperature condition - None | |
Time condition - None | |
Other preconditions - None | |
Terminal status - Terminal 15 | |
Voltage precondition: Vehicle voltage between 9V and 16V | |
Condition for fault memory entry | The fault is entered immediately. |
Action in service | Carry out bus system analysis |
Fault effect and breakdown warning | None |
Driver information | None |
Service instruction | None |