MSS60 Error: CDB6, UNK01
From Wiki-DIY
Information saved in | DME |
Fault code | CDB6 |
Fault text | Diagnosis monitors the required torque. |
Fault description | Malfunction monitoring conditions The fault is detected if the torque is higher than the required torque. |
Condition for fault identification | Test condition: |
Temperature condition - None | |
Time condition - None | |
Other preconditions - None | |
Terminal status - Terminal 15 | |
Voltage precondition: Vehicle voltage between 9V and 16V | |
Condition for fault memory entry | The fault is entered immediately. |
Action in service | Carry out bus system analysis |
Fault effect and breakdown warning | None |
Driver information | None |
Service instruction | None |